Free tools / IFC to schedules
Drop an IFC model and get schedules of its cables, cable containment, pipes and ducts, grouped by system and size with total lengths, plus counts of fittings, terminals and devices. Check the result in a 3D preview and export it to Excel or CSV. The file is read in your browser and is not uploaded.
Drop an IFC file here
.ifc in STEP format: IFC2x3, IFC4 or IFC4x3. No sign-up.
Your file is read by this page, in your browser. It is not uploaded, and nothing from it is sent to 8space or any other server.
The method
.ifc file (IFC2x3, IFC4 or IFC4x3 in STEP format), or load the small sample model to see the output first.IfcCableCarrierSegment); their fittings and junction boxes.IfcDistributionElement, each listed under its IFC class.IfcRelAssignsToGroup in an IfcSystem, IfcDistributionSystem, circuit or building system. An element can be in several systems, or in none.IFC2x3 models write most of these as generic IfcFlowSegment, IfcFlowFitting, IfcFlowTerminal or IfcFlowController occurrences. They are classified through the type object assigned with IfcRelDefinesByType.
Measured or estimated
IfcQuantityLength named Length, that value is used and the row is marked Measured (quantity set). The standard sets are Qto_CableSegmentBaseQuantities, Qto_CableCarrierSegmentBaseQuantities, Qto_PipeSegmentBaseQuantities and Qto_DuctSegmentBaseQuantities in IFC4, and BaseQuantities in IFC2x3.Values are converted from the file’s length unit to metres, including millimetre files and conversion-based units such as feet, and shown to 0.01 m. Only quantities on the element itself count: a length on a type object is a stock length, not a run. Fittings, terminals and devices are counted, not measured.
IfcBuildingElementProxy, or as generic flow elements without a type object, cannot be told apart. The first are not listed at all; the second appear under “Devices & terminals” with their generic class..ifc STEP files are read; very large models are limited by browser memory.Good to know
The exports carry the source file name, IFC schema, extraction date and the basis of every length. CSV is comma-separated with dot decimals for scripts and data tools; the Excel workbook has one sheet per schedule, with lengths stored as numbers rather than text.
No. The page reads the file with JavaScript and WebAssembly inside your browser. The only things downloaded are the page itself, the IFC engine (a WebAssembly file from this site) and, if you ask for it, the sample model. Nothing from your file is sent to 8space or anyone else, and nothing is stored after you close the tab. You can confirm it in your browser’s network panel: choosing a file causes no upload request.
Because the file has no length quantity for those elements. Many authoring tools only write base quantities when that export option is switched on. For such runs the tool measures the element’s geometry instead: the extrusion depth of a straight run, the path of a swept pipe or cable, or the longest extent of its mesh. An estimate ignores anything that was not modelled, such as cable slack, drops to devices and termination allowances, so it is listed on its own row and flagged in the table and in both exports.
IFC files in STEP format with the .ifc extension: IFC2x3, IFC4 and IFC4x3. In IFC2x3, cables, pipes and ducts are all written as IfcFlowSegment and told apart by their type object (for example IfcCableSegmentType); the tool follows that link. Compressed .ifcZIP and .ifcXML files are not read: unzip or re-export them as .ifc first.
An element is listed under “Unassigned” when the file does not assign it to a system: there is no IfcRelAssignsToGroup linking it to an IfcSystem, IfcDistributionSystem or circuit. Either the element is not in a system in the authoring model (cable trays often are not), or systems were not included in the export. The tool does not guess a system from names or connections.
Usual causes: lengths here are rounded to 0.01 m per row; estimated rows measure geometry rather than routed length; an element that belongs to two systems is listed under both, although each tab’s total counts it once; and quantity sets in the file hold whatever the exporter wrote, which is not always what the tool’s own schedule shows. Compare the measured rows first, then look at the estimated ones.
There is no fixed limit, but the whole model has to fit in the memory your browser gives a tab. Above 150 MB the tool asks before it starts. Parsing runs in a background thread, so the page stays usable and shows which step it is on. The 3D preview is capped at about three million vertices; if a model exceeds that, some elements are not drawn, and the schedules still include every element.
In 8space, electrical design, cable routes, calculations and quantities live in one shared MEP workspace, next to the models and documents of the project.